WMEm 197 expert line
WMEm 197 expert line is a Welding inverter, equiped with compact and portable inverter for MMA welding
• Digital MMA machine with Synergic MCU control system
• Real 2-in-1 MMA/LIFT TIG function
• Durable and impact resistance design
• With Electrode rod selection and current default setting function
• 1 Inch LCD screen, easy to operate
• With Hot start(0-100%). Arc force(0-50%)
• Antistick function
• Welding cable
• Returne cable
Out of stock
Payment:
| Main Supply (V/Ph Hz) |
230V / 50–60Hz |
|---|---|
| Input Power (kVA) |
7.8 |
| Setting Range (A) |
10–180 A |
| Rated Input Current (A) |
34 A |
| Rated Duty Cycle (40°C) |
10% @ 180 A |
| No-Load Voltage (V) |
70 V |
| Electrode Size (mm) |
1.6–4.0 |
| Insulated Grade |
H |
| Protection Class |
IP21S |
| Dimensions (mm) |
279 × 116.4 × 182 |
| Weight (kg) |
3.2 |
PDF Spear Parts
Related products
WMEm MIG 250Di
In stock
| MAIN SUPPLY (V/Ph Hz) |
230/1 15% 50/60 |
|---|---|
| MAX. PRIMARY CURRENT (A) |
45 |
| SETTING RANGE (A) |
40-250 |
| MAX. OUTPUT AT 100% DUTY CYCLE (MIG) A/V |
112/19,6 |
| MAX. OUTPUT AT 100% DUTY CYCLE (MMA) A/V |
90/23,6 |
| MAX. OUTPUT AT 100% DUTY CYCLE (TIG) A/V |
112/14,5 |
| RATED WORKING VOLTAGE (V) |
16-26,5 |
| OPEN CIRCUIT VOLTAGE (V) |
69 |
| POWER FACTOR AT MAX. CURRENT |
0,75 |
| EFFICIENCY (ŋ/%) |
85 |
| DIAMETER OF ELECTRODES (mm) |
1,6-4,0 |
| DIAMETER OF WIRE (mm) |
0,6-1,0 |
| PROTECTION CLASS |
IP21S |
| INSULATION CLASS |
H |
| DIMENSIONS (LxBxH cm) |
95x49x89 |
| WEIGHT (kg) |
50 |
WMEm TIG 200i Lynx AC/DC
In stock
| Max. diameter of electrdoe (mm) |
4 |
|---|---|
| Fuse, slow (А) |
16 |
| OKC |
50 |
| Max. outputs at 100% duty cycle, (MMA) (А) |
72 |
| Max. outputs at 100% duty cycle, (TIG) (А) |
89 |
| Max. outputs at 20% duty cycle, (MMA) (А) |
160 |
| Max. outputs at 20% duty cycle, (TIG) (А) |
200 |
| Max. outputs at 60% duty cycle, (MMA) (А) |
92 |
| Voltage (V) |
230 |
| Max. welding current, (MMA) (А) |
160 |
| Min. welding current, (MMA) (А) |
10 |
| Max. welding current, (TIG) (А) |
200 |
| Min. welding current, (TIG) (А) |
10 |
WMEm TIG 180, Lynx
In stock
| Max. diameter of electrdoe (mm) |
4 |
|---|---|
| Fuse, slow (А) |
16 |
| OKC |
50 |
| Max. outputs at 100% duty cycle, (MMA) (А) |
99 |
| Max. outputs at 100% duty cycle, (TIG) (А) |
99 |
| Max. outputs at 30% duty cycle, (MMA) (А) |
180 |
| Max. outputs at 30% duty cycle, (TIG) (А) |
180 |
| Max. outputs at 60% duty cycle, (MMA) (А) |
127 |
| Voltage (V) |
230 |
| Max. welding current, (MMA) (А) |
180 |
| Min. welding current, (MMA) (А) |
10 |
| Max. welding current, (TIG) (А) |
180 |
| Min. welding current, (TIG) (А) |
10 |
WMEm 250 Lynx
Out of stock
| Max. diameter of electrdoe (mm) |
5 |
|---|---|
| Fuse, slow (А) |
16 |
| Open circuit voltage (V) |
80 |
| OKC |
50 |
| Max. outputs at 100% duty cycle, (MMA) (А) |
112 |
| Max. outputs at 20% duty cycle, (MMA) (А) |
250 |
| Max. outputs at 60% duty cycle, (MMA) (А) |
114 |
| Voltage (V) |
230 |
| Max. welding current, (MMA) (А) |
250 |
| Min. welding current, (MMA) (А) |
30 |
WMEm 200 Lynx
Out of stock
| Max. diameter of electrdoe (mm) |
5 |
|---|---|
| Fuse, slow (А) |
16 |
| Open circuit voltage (V) |
82 |
| OKC |
50 |
| Max. outputs at 100% duty cycle, (MMA) (А) |
77 |
| Max. outputs at 15% duty cycle, (MMA) (А) |
200 |
| Max. outputs at 60% duty cycle, (MMA) (А) |
100 |
| Voltage (V) |
230 |
| Max. welding current, (MMA) (А) |
200 |
| Min. welding current, (MMA) (А) |
20 |